Siemens LMO64 / LMO39 Series are microcontroller-based oil burner controls developed for automatic startup sequencing, ignition control, flame supervision, and safe operation of industrial forced-draft oil burners in intermittent mode.
These controllers combine digital burner program sequencing, flame signal monitoring, safety lockout, and operating diagnostics. They support compatible flame detectors for yellow-burning and blue-burning oil flames.
Confirm the supply voltage, burner stages, oil throughput, flame detector type, required safety time, postpurge function, wiring arrangement, and applicable burner control parameters before selecting a replacement unit.
Important: Installation, parameterization, and commissioning must be performed by qualified personnel according to Siemens technical documentation. Plug-in bases and flame detectors are ordered separately.
| Specification | LMO64 Series | LMO39 Series |
|---|---|---|
| Brand | Siemens | Siemens |
| Product Type | Oil Burner Control | Oil Burner Control |
| Control Technology | Microcontroller-based | Microcontroller-based |
| Burner Type | Forced-draft oil burner | Forced-draft oil burner |
| Burner Stages | Single-stage | Single-stage / Two-stage |
| Oil Throughput | Below 30 kg/h | Up to 30 kg/h; above 30 kg/h on certain versions |
| Supply Voltage | AC 230 V (+10% / -15%) | AC 120 V or AC 230 V, depending on model |
| Mains Frequency | 50-60 Hz (±6%) | 50-60 Hz |
| Power Consumption | 12 VA | 12 VA |
| External Primary Fuse | 6.3 A (Slow) | T6.3H250V |
| Compatible Flame Detectors | QRB1 / QRB3 / QRB4 / QRC1 | QRB1 / QRB3 / QRB4 / QRC1 |
| Ignition Safety Time (TSA) | Max. 10 s | 5 s requirement; parameterizable within specified limits |
| Postpurge Time (t8) | 20 s or 90 s, depending on model | Parameterizable |
| Remote Reset | Supported | Supported |
| Status Indication | Multicolor LED | Multicolor LED |
| Safety Class | Class I | Class I |
| Degree of Protection | IP40 when correctly mounted | IP40 when correctly mounted; IP10 if RJ11 jack is uncovered |
| Operating Temperature | -5 to +60 °C | -20 to +60 °C |
| Approximate Weight | 200 g | 160 g |
| Reference Standard | DIN EN 298 | DIN EN 298 |
| Reference Document | CC1N7138en (30.09.2025) | CC1N7154en (07.09.2023) |
| Model | Voltage | Stages | Prepurge (t1 / t1') | Safety Time (TSA) | Postpurge (t8) |
|---|---|---|---|---|---|
| LMO64.300C2 | AC 230 V | 1 | 15 / 16 s | 10 s | 20 s |
| LMO64.301C2 | AC 230 V | 1 | 15 / 16 s | 10 s | 90 s |
| LMO64.302C2 | AC 230 V | 1 | 15 / 16 s | 10 s | 20 s |
LMO64 Note: LMO64.302C2 is available on request. Its postignition time differs from the other versions. The listed program times are manufacturer-specified limits.
| Model | Voltage | Stages | Safety Time Requirement | Postpurge |
|---|---|---|---|---|
| LMO39.100C1 | AC 120 V | 1 / 2 | 5 s | Parameterizable |
| LMO39.100C2 | AC 230 V | 1 / 2 | 5 s | Parameterizable |
Technical Note: The LMO39 safety time and operating sequences must be configured according to the application and manufacturer limits. Values in the type summary are not necessarily the final commissioned settings. Refer to Siemens Datasheets CC1N7138en and CC1N7154en for installation and replacement.
| Specification | LMO64 Series | LMO39 Series |
|---|---|---|
| Brand | Siemens | Siemens |
| Product Type | Oil Burner Control | Oil Burner Control |
| Control Technology | Microcontroller-based | Microcontroller-based |
| Burner Type | Forced-draft oil burner | Forced-draft oil burner |
| Burner Stages | Single-stage | Single-stage / Two-stage |
| Oil Throughput | Below 30 kg/h | Up to 30 kg/h; above 30 kg/h on certain versions |
| Supply Voltage | AC 230 V (+10% / -15%) | AC 120 V or AC 230 V, depending on model |
| Mains Frequency | 50-60 Hz (±6%) | 50-60 Hz |
| Power Consumption | 12 VA | 12 VA |
| External Primary Fuse | 6.3 A (Slow) | T6.3H250V |
| Compatible Flame Detectors | QRB1 / QRB3 / QRB4 / QRC1 | QRB1 / QRB3 / QRB4 / QRC1 |
| Ignition Safety Time (TSA) | Max. 10 s | 5 s requirement; parameterizable within specified limits |
| Postpurge Time (t8) | 20 s or 90 s, depending on model | Parameterizable |
| Remote Reset | Supported | Supported |
| Status Indication | Multicolor LED | Multicolor LED |
| Safety Class | Class I | Class I |
| Degree of Protection | IP40 when correctly mounted | IP40 when correctly mounted; IP10 if RJ11 jack is uncovered |
| Operating Temperature | -5 to +60 °C | -20 to +60 °C |
| Approximate Weight | 200 g | 160 g |
| Reference Standard | DIN EN 298 | DIN EN 298 |
| Reference Document | CC1N7138en (30.09.2025) | CC1N7154en (07.09.2023) |
| Model | Voltage | Stages | Prepurge (t1 / t1') | Safety Time (TSA) | Postpurge (t8) |
|---|---|---|---|---|---|
| LMO64.300C2 | AC 230 V | 1 | 15 / 16 s | 10 s | 20 s |
| LMO64.301C2 | AC 230 V | 1 | 15 / 16 s | 10 s | 90 s |
| LMO64.302C2 | AC 230 V | 1 | 15 / 16 s | 10 s | 20 s |
LMO64 Note: LMO64.302C2 is available on request. Its postignition time differs from the other versions. The listed program times are manufacturer-specified limits.
| Model | Voltage | Stages | Safety Time Requirement | Postpurge |
|---|---|---|---|---|
| LMO39.100C1 | AC 120 V | 1 / 2 | 5 s | Parameterizable |
| LMO39.100C2 | AC 230 V | 1 / 2 | 5 s | Parameterizable |
Technical Note: The LMO39 safety time and operating sequences must be configured according to the application and manufacturer limits. Values in the type summary are not necessarily the final commissioned settings. Refer to Siemens Datasheets CC1N7138en and CC1N7154en for installation and replacement.