Siemens Burner Controllers LME7 Series are microprocessor-based industrial burner controls developed for automatic startup, flame supervision, and safety management of medium- to large-capacity gas and oil burners.
The LME7 Series supports multistage and modulating forced-draft burners as well as compatible atmospheric gas burners in intermittent operation. Its operating functions include burner program sequencing, air pressure supervision, undervoltage detection, and safety lockout.
The family includes LME71, LME72, and LME73. Depending on the model and the selected PME7 program module, the controllers support mechanical or pneumatic fuel-air ratio systems, air damper actuator control, and PWM fan operation.
| Series | Key Functions | Flame Supervision |
|---|---|---|
| LME71 | Digital burner sequencing and parameter-dependent PWM fan control | Ionization Probe / QRA2 / QRA4 / QRA10 |
| LME72 | Burner sequencing with actuator control output | Ionization Probe |
| LME73 | Burner sequencing with actuator control and broader optical flame detector compatibility | Ionization Probe / QRA2 / QRA4 / QRA10 / QRB1 / QRB3 / QRB4; QRC on supported variants |
The controller uses a compatible PME7 program module to define burner operating functions and sequences. Parameter configuration and diagnostics are available through Siemens AZL2 or ACS410 using suitable interface accessories.
Depending on model and configuration, the system can support analog load control signals, air damper positioning, or PWM fan operation. These features are model-specific and must not be assumed to be available on every LME7 controller.
Verify the supply voltage, fuel type, flame detector compatibility, required actuator or PWM fan functions, load control inputs, wiring arrangement, and compatible PME7 program module before selecting an LME71, LME72, or LME73 controller.
Important: The basic LME7 unit has an IP00 protection rating. The burner or boiler manufacturer must ensure appropriate IP40 installation protection. Commissioning and safety-related parameter changes must be performed by qualified personnel according to Siemens technical documentation.
| Specification | Technical Data |
|---|---|
| Brand | Siemens |
| Product Series | LME7 Series |
| Models | LME71 / LME72 / LME73 |
| Product Type | Microprocessor-based Burner Control |
| Burner Application | Multistage / Modulating Forced-Draft Burners and Compatible Atmospheric Gas Burners |
| Fuel Type | Oil / Gas, depending on configuration |
| Operating Mode | Intermittent Operation |
| Supply Voltage | 120 V AC or 230 V AC, depending on model |
| Supply Frequency | 50 / 60 Hz |
| Internal Power Consumption | Typically <10 W |
| External Primary Fuse | Max. 6.3 A, slow-blow |
| Flame Detection | LME71: Ionization / QRA2 / QRA4 / QRA10; LME72: Ionization; LME73: Ionization / QRA2 / QRA4 / QRA10 / QRB1 / QRB3 / QRB4, QRC on supported variants |
| Air Pressure Supervision | Air Pressure Switch Monitoring |
| Analog Load Control Inputs | 0-10 V DC, 0/4-20 mA, 0-135 Ohm on supported models |
| Fan Control | PWM Control Output on supported LME71 configurations |
| Actuator Control | Control output on LME72 / LME73 |
| Program Module | Compatible Siemens PME7 Series |
| Parameter Adjustment | AZL2 / ACS410 |
| Status Indication | 3-Color LED; 3 x 7-Segment Display on LME71 / LME73 |
| Flame Failure Response Time | Max. 1 s, subject to detection configuration |
| Operating Temperature | -40 to +60 °C |
| Storage Temperature | -40 to +70 °C |
| Relative Humidity | <95% RH |
| Degree of Protection | IP00 (Basic Unit); IP40 installation protection required |
| Weight | Approx. 490 g |
| Installation Altitude | Max. 2,000 m above sea level |
| Designed Lifetime | 250,000 burner startup cycles or approx. 10 years under specified conditions |
| Applicable Standards | DIN EN 298, DIN EN 1643, DIN EN 13611, DIN EN 60730-2-5 |
| Technical Reference | Siemens CC1N7105en (18.01.2024) |
| Model | Voltage | UV QRA | QRB | QRC | Actuator Control | PWM Fan |
|---|---|---|---|---|---|---|
| LME71.000A1 | 120 V AC | Yes | No | No | No | Supported* |
| LME71.000A2 | 230 V AC | Yes | No | No | No | Supported* |
| LME71.901A2 | 230 V AC | Yes | No | No | No | Subject to configuration |
| LME72.000A2 | 230 V AC | No | No | No | Yes | No |
| LME73.000A1 | 120 V AC | Yes | Yes | No | Yes | No |
| LME73.000A2 | 230 V AC | Yes | Yes | Yes | Yes | No |
Technical Note: *PWM fan control requires the applicable PME7 program and parameter configuration. Flame detector options, analog inputs, and actuator functions vary by model. LME71.901A2 and LME72.000A2 may be available on request. Specifications are based on Siemens CC1N7105en. Consult the correct PME7 program module documentation before installation.
| Specification | Technical Data |
|---|---|
| Brand | Siemens |
| Product Series | LME7 Series |
| Models | LME71 / LME72 / LME73 |
| Product Type | Microprocessor-based Burner Control |
| Burner Application | Multistage / Modulating Forced-Draft Burners and Compatible Atmospheric Gas Burners |
| Fuel Type | Oil / Gas, depending on configuration |
| Operating Mode | Intermittent Operation |
| Supply Voltage | 120 V AC or 230 V AC, depending on model |
| Supply Frequency | 50 / 60 Hz |
| Internal Power Consumption | Typically <10 W |
| External Primary Fuse | Max. 6.3 A, slow-blow |
| Flame Detection | LME71: Ionization / QRA2 / QRA4 / QRA10; LME72: Ionization; LME73: Ionization / QRA2 / QRA4 / QRA10 / QRB1 / QRB3 / QRB4, QRC on supported variants |
| Air Pressure Supervision | Air Pressure Switch Monitoring |
| Analog Load Control Inputs | 0-10 V DC, 0/4-20 mA, 0-135 Ohm on supported models |
| Fan Control | PWM Control Output on supported LME71 configurations |
| Actuator Control | Control output on LME72 / LME73 |
| Program Module | Compatible Siemens PME7 Series |
| Parameter Adjustment | AZL2 / ACS410 |
| Status Indication | 3-Color LED; 3 x 7-Segment Display on LME71 / LME73 |
| Flame Failure Response Time | Max. 1 s, subject to detection configuration |
| Operating Temperature | -40 to +60 °C |
| Storage Temperature | -40 to +70 °C |
| Relative Humidity | <95% RH |
| Degree of Protection | IP00 (Basic Unit); IP40 installation protection required |
| Weight | Approx. 490 g |
| Installation Altitude | Max. 2,000 m above sea level |
| Designed Lifetime | 250,000 burner startup cycles or approx. 10 years under specified conditions |
| Applicable Standards | DIN EN 298, DIN EN 1643, DIN EN 13611, DIN EN 60730-2-5 |
| Technical Reference | Siemens CC1N7105en (18.01.2024) |
| Model | Voltage | UV QRA | QRB | QRC | Actuator Control | PWM Fan |
|---|---|---|---|---|---|---|
| LME71.000A1 | 120 V AC | Yes | No | No | No | Supported* |
| LME71.000A2 | 230 V AC | Yes | No | No | No | Supported* |
| LME71.901A2 | 230 V AC | Yes | No | No | No | Subject to configuration |
| LME72.000A2 | 230 V AC | No | No | No | Yes | No |
| LME73.000A1 | 120 V AC | Yes | Yes | No | Yes | No |
| LME73.000A2 | 230 V AC | Yes | Yes | Yes | Yes | No |
Technical Note: *PWM fan control requires the applicable PME7 program and parameter configuration. Flame detector options, analog inputs, and actuator functions vary by model. LME71.901A2 and LME72.000A2 may be available on request. Specifications are based on Siemens CC1N7105en. Consult the correct PME7 program module documentation before installation.
บริษัท บุญเยี่ยมและสหาย จำกัด
Visit Supplier Profile